Q-on I-Series, S-Series and Rugged UPS range in an industrial interior
Q-ON UPS SYSTEMS

Power for every
scale of business.

From essential electronics to demanding industrial loads. Explore the Q-on family, compare the technical essentials and find the right protection for your operation.

Explore the range
I-SeriesS-SeriesRuggedMonitoring
LITHIUM-ION UPS

Q-on I-Series

Q-on I-Series UPS, shown without external batteries

Scalable 5 kVA power protection for connected workplaces, retail systems and server rooms. Pair online UPS protection with lithium-ion storage and size the battery reserve around the runtime your operation needs.

  • True double-conversion and pure sine-wave output
  • 48V battery platform and 60A AC charging
  • Scalable parallel configurations; single- and three-phase options
Discuss your application
Q-on I-Series · published technical data
Model5KL-48V
Rated output5,000 VA / 5,000 W
Input / output voltage220 / 230 / 240 VAC
AC to battery transferZero
WaveformPure sine wave
Line / ECO / battery efficiency93% / 99.5% / 91%
Battery DC voltage48 VDC
Maximum charging current60 A
CommunicationRS232 & USB
Dimensions (D × W × H)465 × 190 × 318 mm
Net weight15.5 kg
SINGLE-PHASE UPS

Q-on S-Series

Q-on S-Series 6kVAQ-on S-Series 10kVA

Single-phase online protection in 1, 3, 6 and 10 kVA models for workstations, networks, telecoms and sensitive equipment. A practical range for clean, continuous power where a small footprint matters.

  • Online double-conversion with output power factor 1
  • DSP control, programmable LCD and ECO mode
  • USB monitoring and intelligent communications slot
Discuss your application
Technical essentials
Range1–10 kVA; model-specific configuration
TopologySingle-phase UPS
Battery configuration16 / 18 / 20 batteries for supported 6 and 10 kVA models
Input PFC0.99
Operating modesOnline / ECO
Maintenance bypass6 and 10 kVA models
ProtectionOverload, short-circuit and over-temperature protection
THREE-PHASE TRANSFORMER-BASED UPS · 10–600 kVA

Q-on Rugged

Q-on Rugged UPS cabinet
THREE-PHASE POWER PROTECTION

Engineered for
demanding loads.

Explore the Rugged range below for model-specific capacity, dimensions and electrical requirements.

View Rugged technical specifications

Transformer-based protection designed for demanding Southern African operating conditions. Built for industrial controls, manufacturing and larger critical-power applications.

  • Online double-conversion with galvanic isolation
  • Coated circuit boards and independent ventilation
  • Monitoring and parallel options for the selected configuration
Discuss your application
Technical essentials
Q-on Rugged range10–600 kVA; three-phase, transformer-based UPS
ArchitectureThree-phase, transformer-based UPS
Range illustrated10–200 kVA
ApplicationIndustrial and business-critical loads
ConfigurationModel-specific input, output and battery requirements; refer to the technical sheet
Published output ratings10/8, 15/12, 20/16, 30/24, 40/32, 60/48, 80/64, 100/80, 120/96, 160/128, 200/160 kVA/kW
Nominal input / output3 × 380 / 400 VAC (3Ph + N)
Input range285–475 VAC
Output THDv<2% linear load; <5% non-linear load
Static bypass transferZero
Nominal battery voltage384 VDC with 32 × 12 V batteries

The linked technical sheet covers models up to 200 kVA. Contact Powermode for specifications of larger models.

Compare Rugged model specifications +
POWERMODE MONITORING PORTAL (PMP)
CONNECTED 7×24

Your standby power.
Always in view.

IoT-based visibility across your power infrastructure. All UPS brands supported, with alerts, status and uptime statistics that help you track standby health and return on investment.

  • Alerts, status & uptime stats
  • Standby health ROI
  • All UPS brands supported
Connect your sites to PMP
PowermodePMP / INTERACTIVE DEMO
YOUR STANDBY POWER ESTATE

See the whole picture.

SAMPLE DATA
On mainsIllustrative weekly report
Battery charge96%
State of health94%
Equivalent cycles0.8Full-charge equivalent
BATTERY OPERATIONTrading / Non-trading
Trading 3.2 hNon-trading 1.8 hTotal 5.0 h
Downtime in trading hours0.0 hDowntime after trading0.0 h

Review battery health alongside runtime and downtime to plan maintenance.

01 / NETWORK

SNMP

TCP-IP / Ethernet

02 / SERIAL

MODBUS RTU

RS485/232 · USB

YOUR QUESTIONS

Before you choose your UPS.

What information is needed to size my UPS?

Share the equipment you need to keep running, its power requirements, your required runtime and the site location. Include your electrical supply details and any existing generator or battery system so our team can confirm a suitable combination.

Can I rent a UPS rather than buy one?

Powermode offers UPS rental proposals. Ask for a system matched to your load and runtime, with the monitoring, battery and service responsibilities clearly set out in the agreement.

TURNKEY POWER SPECIALISTS

Let’s power your next move.

Tell us your critical load, runtime and site conditions. We’ll help specify the Q-on range and support plan.

Talk to Powermode